Bosch Appliances Home Security System MIC WKT User Manual

MIC-WKT and MIC-WKT-IR  
Installation Manual  
Bosch Security Systems  
EN  
Installation and Operation Manual  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 3  
Introduction............................................................. 1-7  
Versions............................................................................................. 1-7  
Features............................................................................................. 1-7  
Unpacking.......................................................................................... 1-8  
Packaging Contents........................................................................... 1-8  
Installation…………………………………… ……… 2-9  
705-200 Washer Pump Drive Card Functionality…..………………… 2-9  
Installation ……………………………………………….……………….. 2-9  
Connecting the washer pump to the IR power supply……………….. 2-11  
Technical Specifications......................................... 3-13  
Technical Specifications ……………………………………………….. 3-13  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 4  
1. Read all instructions prior to installation.  
2. Keep this manual for future reference.  
3. Heed all warnings.  
Safety Precautions  
The following symbols are used throughout this manual please pay careful  
attention to their meaning.  
4. Install according to manufacturer’s instructions.  
5. Qualified persons only should install this product, if in doubt consult a qualified  
installer.  
6. Use correct electrostatic discharge handling procedures when handling printed  
circuit boards to avoid damage to electro-sensitive components.  
7. Do not install near any strong heat sources such as furnaces.  
8. Never push objects or pour liquids into the product enclosure as this can cause a  
fire or electrical shock hazard.  
The lightning flash with an arrowhead symbol within a  
triangle is intended to alert the user to the presence of non-  
insulated “dangerous voltage” within the product’s  
enclosure that may be of sufficient magnitude to constitute  
a risk of electric shock to persons.  
9. Only use electronic cleaning solvent in the unlikely event of the card requiring  
cleaning.  
10. Ensure that the product is correctly earthed.  
11. Use only the power sources indicated in this user guide and ensure that the  
current rating of the supply cable is adequate for the product.  
12. Do not overload power supply sockets as this can be a fire or electrical shock  
hazard.  
The exclamation point within a triangle is intended to alert  
the user to the presence of important safety, operating and  
maintenance (servicing) instructions in the literature  
accompanying the appliance.  
13. In the event of failure do not attempt to service this product yourself, please  
contact Bosch Security Systems for assistance.  
14. Only use approved attachments or accessories specified by the manufacturer. Any  
changes or modifications made to the equipment, not expressly approved in writing  
by Bosch Security Systems, could prevent proper or safe operation of the product  
and will invalidate the warranty.  
Important Safety Instructions  
CAUTION  
TO REDUCE THE RISK OF ELECTRICAL SHOCK,  
DISCONNECT POWER SUPPLY BEFORE OPENING THE  
POWER SUPPLY UNIT.  
POWER DISCONNECT: POWER SUPPLY UNITS HAVE  
POWER SUPPLIED WHENEVER THE POWER CORD IS  
INSERTED INTO THE POWER SOURCE  
15. Please dispose of disused electrical & electronic equipment at an environmentally  
compatible recycling facility (contact Bosch Security Systems for further details).  
WARNING  
INSTALLATION SHOULD BE CARRIED OUT BY  
QUALIFIED PERSONNEL ONLY IN ACCORDANCE  
WITH THE APPLICABLE LOCAL CODES.  
BOSCH SECURITY SYSTEMS ACCEPTS NO LIABILITY  
FOR ANY DAMAGES OR LOSSES CAUSED DUE TO  
INCORRECT OR IMPROPER INSTALLATION  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 5  
Reference  
This product complies with the following EC directives:-  
Glossary of Terms  
EMC Directive (89/336/EC as amended)  
Machinery Directive (98/37/EC)  
LV Directive (73/23/EC)  
PTZ  
-
-
-
-
Pan/Tilt/Zoom  
Power Supply Unit  
Infra Red  
PSU  
IR  
Camset  
please  
Bosch Security Systems configuration & set up software,  
RoHS (Restriction of Hazardous substances) 2002/95/EC  
WEEE (Waste Electrical & Electronic Equipment) 2002/96/EC  
This equipment contains electrical or electronic components  
that must be recycled properly to comply with Directive  
2002/96/EC of the European Union regarding the disposal of  
waste electrical and electronic equipment (WEEE). Contact  
your local supplier for procedures for recycling this  
equipment.  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 6  
CHAPTER 1  
Introduction  
The MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits provide the  
required fittings to enable third party washer kits to remotely clean the window of  
the MIC400 camera.  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 7  
Versions  
This card is only required for MIC400 Power Supply Units which do not support  
integrated washer or alarm operations, these are the following MIC400 Power  
Supply Units:-  
This manual covers the installation and operation of Bosch Security Systems  
MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits for the MIC400 range  
of PTZ Cameras.  
MIC-240PSU  
MIC-12PSU  
MIC-24PSU  
MIC-115PSU  
The MIC-WKT kit consists of the 705-200 Washer Pump Drive Card, a 5mm single  
jet washer nozzle and two (2) brackets to allow mounting of the washer nozzle on  
to a MIC400 camera base or corner mount bracket (CMB) utilising the M8 x 20mm  
fixing bolts holding the camera base or between wall and corner mount brackets.  
The following MIC400 Power Supply Units include 4 –Alarm inputs and a Washer  
Pump Drive function as standard and details of setting up the washer drive are  
included later in this manual, you may also refer to the MIC400 Power Supply  
Units Installation and Operation Manual instead :-  
The MIC-WKT-IR kit is identical to the MIC-WKT kit except for lacking the 705-200  
Washer Pump Drive Card as this function is provided as standard on all MIC400 IR  
Power Supplies.  
The washer pump, reservoir bottle & 5mm tubing are not supplied by Bosch  
Security Systems and will need to be purchased separately to suit the particular  
installation.  
MIC-IR-240PSU  
MIC-IR-12PSU  
MIC-IR-24PSU  
MIC-IR-115PSU  
The 705-200 is a Printed Circuit Board as shown below and plugs directly into Non  
IR Power Supply Units for the MIC400 PTZ Camera.  
Features  
The MIC-WKT and MIC-WKT-IR Kits have the following features:  
Washer Pump Drive Card (for MIC-WKT)  
Easy installation into MIC400 non IR power supply units (for MIC-WKT)  
Push to Test button  
Choice of mounting brackets to suit most installations  
Washer Nozzle  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 8  
Unpacking  
CHAPTER 2  
Installation  
WARNING: Use proper ESD handling precautions to avoid  
705-200 Washer Pump Drive Card Functionality  
electrostatic discharge. Wear a grounded wrist strap to  
prevent damage when handling electro-sensitive printed  
circuit boards.  
The 705-200 Washer Pump Drive Card provides an output relay (SK1) rated at  
240vAC up to 5 Amps, wiring for this supply must be provided by the installer and  
it is strongly recommended that this supply is externally fused.  
Check the exterior of the packaging for visible damage. If any items  
appear to have been damaged in transit please inform the shipping  
company.  
A push to test button (SW1) is also provided to test the pump operation and expel  
air to prime the pump ready for operation.  
The drive signal Washer Dr is a TTL signal generated by the MIC400 camera, this  
TTL signal causes the relay drive transistor to switch on thus energizing the relay  
and closing the relay contacts thereby activating the supply to the washer pump.  
Unpack the unit carefully; although ruggedized this is electronic equipment  
and should be handled with care.  
Do not use if any component appears to be damaged. Please contact  
Bosch Security Systems in the event of damaged goods.  
The shipping cartoon is the best way to transport the unit, save it & all  
other packaging materials for future use. If the unit must be returned, use  
the original packing materials.  
Packaging Contents  
Please check for the following contents for the MIC-WKT Washer Kit  
MIC-WKT and MIC-WKT-IR Washer Kit Installation Manual (this Booklet)  
705-200 Washer Pump Drive Card  
Single Jet Washer Nozzle (5mm)  
Two (2) Brackets for mounting the Washer Nozzle (200-007 & 200-008)  
For the MIC-WKT-IR the following items should be included:-  
MIC-WKT and MIC-WKT-IR Washer Kit Installation Manual (this Booklet)  
Single Jet Washer Nozzle (5mm)  
Two (2) Brackets for mounting the Washer Nozzle (200-007 & 200-008)  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 9  
Figure 1:- MIC400 Non-IR Power Supply PCB Layout  
Installation of the 705-200 Washer Pump Drive Card  
CAUTION: Electrical Danger: Ensure all power is disconnected  
before opening or working upon the MIC400 Power Supply Unit.  
Installation must be carried out by suitably qualified persons &  
all local safety regulations should be followed.  
Installation of the 705-200 Washer Pump Drive Card is best performed prior to  
installing the Power Supply in the field. To install the 705-200 Washer Pump  
Drive Card, please do the following:-  
1. The power supply unit must be switched off and unplugged prior to  
carrying out any work.  
A. Right hand - Add on  
card support spacers &  
holes  
2. Ensure that the four (4) card spacer supports fitted in the power supply are  
positioned in the left and right most mounting holes on the power supply  
printed circuit board, so that the MIC-WSH card is supported in each  
corner.  
3. Should you need to reposition the card spacers first remove the four (4)  
screws holding the power supply PCB to the enclosure, turn the PCB over  
and remove the two (2) card spacer supports, these spacers should be re-  
fixed at the correct positions shown as A and B on Figure 1 below.  
B. Centre – Add on  
C. Connection  
card support spacers &  
Header CN1  
holes  
Figure 2:- 705-200 Washer Pump Drive Card PCB Layout  
4. Insert the 705-200 Washer Pump Drive Card so that the connector  
labelled CN1 as shown on Figure 2 below plugs into the CN1 header on  
the Power Supply labelled C on Figure 1. Then fix to the card spacer  
supports using M3x6 screws.  
5. The 705-200 Washer Pump Drive Card is now ready to accept third party  
washer pump electrical connections. Please see Installation of the  
Washer Pump for more details.  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 10  
5. Open the PSU lid and locate the washer pump drive header SK1 at the  
upper left hand side of the 705-200 Washer Pump Drive Card (see  
figure 2).  
Installation  
CAUTION: Electrical Danger: Ensure all power is  
disconnected before opening or working upon the MIC400  
Power Supply Unit.  
6. Feed the washer pump drive power cable through the one of the  
weatherproof glands on the Power Supply Unit, leave sufficient slack to  
connect to the SK1 terminal then tighten the gland. Bosch Security  
Systemsstrongly recommends that the washer pump power cable  
should be protected externally by a suitably rated fuse.  
Installation must be carried out by suitably qualified persons  
7. Connect the washer pump drive power cable to the 705-200 Washer  
Pump Drive Card using the SK1 terminal, the connections required are  
shown below:-  
WARNING: The 705-200 may be connected via header SK1  
to 240vAC or 24vAC pump systems. A correctly rated fuse  
MUST be fitted for the expected current draw of the pump  
system. Nominally this would be 2.5A for 240V and 5A for  
24V pumps. In addition Bosch Security Systems  
recommends that the external power supply feeding the  
washer pump is protected with a suitably rated fuse.  
Bosch Security Systems accepts no liability for damage or  
injury caused by incorrect fuse installation.  
SK1  
Pump Connections  
Live  
1
2
3
4
Neutral  
Pump Neutral  
Pump Live  
To connect a third party washer pump, please do the following:-  
8. Secure all external pipe work and cabling, fill the reservoir then plug in  
the MIC400 Power Supply Unit.  
1. Fit the washer nozzle to the appropriate bracket (wall or corner mount)  
and then fix the washer nozzle bracket to the wall or corner bracket  
using one of the M8 fixing bolts, ensure the washer nozzle points  
towards the camera and does not obstruct the camera view see photo’s  
on page 12 and 13 for installation of washer nozzle bracket.  
9. Press the push to test button (SW1) to test the pump operation, hold  
button SW1 down to expel the air from the tubing & prime the pump for  
operation.  
10. When the pump is primed, close the MIC400 Power Supply Unit.  
2. Fit the washer pump and reservoir in a suitable location taking all  
necessary safety precautions, observing the manufacturers instructions  
and all applicable local building codes.  
11. Point the MIC400 at the wash nozzle and set the wash wipe position via  
the control room interface or via a laptop using Camset.  
3. Connect the 5mm tubing from the pump to the washer nozzle.  
4. Ensure the MIC400 Power Supply Unit is completely disconnected from  
the power source.  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 11  
To connect a washer pump to the IR power supply, please do the following:-  
Connecting a Washer Pump to Infra Red Power Supplies  
CAUTION: Electrical Danger: Ensure all power is  
disconnected before opening or working upon the MIC400  
Power Supply Unit.  
Installation must be carried out by suitably qualified  
persons & all local safety regulations should be followed.  
Bosch Security Systems Infra Red Power supplies have an integrated Washer  
Pump Drive and 4 – Alarm input built into the printed circuit board for the following  
power supplies:-  
MIC-IR-240PSU  
MIC-IR-12PSU  
MIC-IR-24PSU  
MIC-IR-115PSU  
CAUTION: This washer pump drive is suitable for  
230v/110v AC pumps ONLY (HD7 outputs at 230VAC or  
110VAC depending on PSU link selection) if a lower  
voltage pump is desired then an external transformer of a  
suitable type must be used, please refer to suitably  
qualified personnel in this instance.  
Figure 3 MIC400IR Power Supply Printed Circuit Board Diagram  
1. Fit the washer nozzle to the appropriate bracket (wall or corner mount)  
and then fix the washer nozzle bracket to the wall or corner bracket  
using one of the M8 fixing bolts, ensure the washer nozzle points  
towards the camera and does not obstruct the camera view.  
2. Fit the washer pump and reservoir in a suitable location taking all  
necessary safety precautions, observing the manufacturers instructions  
and all applicable local building codes.  
3. Connect the 5mm tubing from the pump to the washer nozzle.  
4. Ensure the MIC400 Power Supply Unit is completely disconnected from  
the power source.  
5. Locate the 2 way terminal block HD7 in the bottom left hand corner of  
the IR power supply as shown on Figure 3, this outputs electrical  
current at 230VAC or 110VAC ONLY depending upon PSU link  
selection.  
6. Feed the washer pump power cable through one of the weatherproof  
glands in the power supply enclosure, leave sufficient slack to connect  
the cable to HD7.  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 12  
Photo showing installation of the washer pump bracket and nozzle installed  
on the MIC 4” PCD foot  
Signal  
Connection  
Ident  
Washer Pump Live  
HD7 pin 1  
HD7 pin 2  
L
Washer Pump Neutral  
N
7. Tighten the weatherproof gland then connect the pump power cable to  
the appropriate terminals (Live or Neutral) taking care to observe the  
correct polarity as shown below. Bosch strongly recommends that the  
washer pump power cable should be protected externally by a suitably  
rated fuse.  
8. Secure all external pipe work and cabling, fill the washer reservoir then  
plug in the MIC400 Power Supply Unit.  
9. Press the push to test button (SW1) to test the pump operation, hold  
button SW1 down to expel the air from the tubing and prime the pump  
for operation.  
10. When the pump is primed, close the MIC400 Power Supply Unit.  
11. Point the MIC400 at the wash nozzle and set the wash wipe position via  
the control room interface or via a laptop using Camset.  
Bosch Security Systems  
Issue 1  
 
MIC-WKTI and MIC-WKT-IR Installation Manual  
EN | 13  
Contact  
CHAPTER 3 Technical Specifications  
Americas  
705-200 Washer Pump Drive Card Dimensions  
125mm (W) x 25 mm (H) x 60mm (D)  
Bosch Security Systems Inc  
850 Greenfield Road  
Lancaster  
Pennsylvania 17601  
USA  
Telephone  
Fax  
+1 888-289-0096  
+1 585-223-9180  
Europe, Middle East, Africa  
Bosch Security Systems B.V  
P.O Box 80002  
5600 JB Eindhoven  
The Netherlands  
Phone  
Fax  
+31 40 2577 284  
+31 40 2577 330  
Asia-Pacific  
Bosch Security Systems Pte Ltd  
38C Jalan Pemimpin  
Singapore 577180  
Phone  
Fax  
+65 6319 3450  
+65 6319 3499  
© Bosch Security Systems B.V, 2011, Data subject to change without  
Bosch Security Systems  
Issue 2  
 

Black Box Computer Hardware Video to VGA Converter User Manual
Bosch Appliances Universal Remote EX12LED User Manual
Bosch Power Tools Saw CRS180B User Manual
Bose Speaker System L1 Model II User Manual
Bostitch Air Compressor CAP60P OF User Manual
Carrier Heat Pump 50PEC09 18 User Manual
Casio Projector XJS38 User Manual
Chauvet Outdoor Timer SF 4005 User Manual
Chromalox Electric Heater CAB User Manual
Chromalox Thermostat GNIT 5 User Manual